We Refuse to Put Your Products at Risk
Reliable, Superior Performance

   
 
Cycles
ESD S1.1 sample minimum life 8,000
ESD S1.1 all samples average life 16,000
TEST COMPLETED 2009-02-20 through 2009-03-04
Snap One Sample 1                                
195,085
Snap One Sample 2
243,343
Snap One Sample 3
151,550
Snap One Sample 4
211,055
TEST COMPLETED 2006-02-20
Jewel Dual Wire Sample 1

11,762,000

Jewel Dual Wire Sample 2

11,762,000

 
TEST COMPLETED 2003-06-25
Jewel Rapid Retraction Sample 1 52,576,321
Jewel Rapid Retraction Sample 2 52,976,392
Jewel Rapid Retraction Sample 3 51,992,914
Jewel Rapid Retraction Sample 4 53,012,060
 
TEST CONCLUDED 2000-12-01
Black Relaxed Retraction Sample 1 1,176,172
Black Relaxed Retraction Sample 2 932,147
Black Relaxed Retraction Sample 3 1,217,333
Black Relaxed Retraction Sample 4 976,451

 

Reliable Circuit Connections Bending Life Test per ESD S1.1

Per ESD Handbook TR20.20 paragraph 5.3.2.2.2 Wrist Strap Ground Cord "At first glance, the ground cord appears to be a relatively simple assembly. However, the design requirements are considerable, given the wide range of user applications and the durability requirements of constant tugging, flexing, and dragging over the edge of workstation tops and equipment chassis."



Per ESD S1.1, Coil Cords should be tested on a machine like the one shown here.