50621-CONTROLLER, ION PYTHON, FOOT SWITCH, 220VAC NIST

50621-CONTROLLER, ION PYTHON, FOOT SWITCH, 220VAC NIST              

50621 - Ion Python with Foot Switch and Controller, 220VAC

Internet List Price Fax / Email List Price
Qty: 1 $1343.79
Qty: 1 $1478.17

In-stock orders will ship in 3 business days or less after receipt of order.

Stock: 0

Other Quantities - Contact Us.


This item is built-to-order. Please contact Customer Service for Lead Time. Orders will be accepted for a minimum of 1.

Stock Location: CHINO, CA, 3661 WALNUT AVENUE

Country Of Origin: USA

Sold Per: EA

Gross Weight2: 6.90 lb

2The weight listed is gross product weight including standard packaging, actual shipment weight may vary.

Quantity:







Bookmark and Share
  • Rugged construction
    Long life
  • Balance adjustable ±20 voltage offset
    Flexibility in uses
  • Replaceable air filter
    Keeps air free of contaminants
  • Stainless steel case
    Corrosion resistant
  • Stationary hose
    Can be activated with foot pedal
  • Adjustable 30 PSI to 100 PSI air pressure
    Adjustable to meet requirements of the application
  • < 1 sec discharge time at 6" 
  • Made in the United States of America

The Ion Python is a point-of-use ionizer using compressed air or nitrogen to neutralize electrostatic charges from a small, defined area and/or to facilitate removal of charged particles. These ready-to-use units are designed for use in applications and areas where ElectroStatic Attraction contamination create manufacturing or handling problems (Ref: ESD Handbook TR 20.20 paragraph 5.3.6.5.2.4 Point of Use Ionization). The Ion Python meets or exceeds the recommended technical requirements of ANSI/ESD S20.20 tested in accordance with ANSI/ESD S3.1.

NOTE: Air nozzles are recommended for intermittent applications. They require filtered, dry, non-combustible gases, such as compressed shop air or nitrogen. If using nitrogen, contact the factory for modifications and adjustments needed. 

“Necessary non-conductors in the environment cannot lose their electrostatic charge by attachment to ground. Ionization systems provide neutralization of charges on these necessary non-conductive items (circuit board materials and some device packages are examples of necessary non-conductors). Assessment of the ESD hazard created by electrostatic charges on the necessary nonconductors in the work place is required to ensure that appropriate actions are implemented, commensurate with risk to ESDS [ESD sensitive] items”. (ANSI/ESDS20.20-2007 Foreword)

 

“In order to mitigate field-induced CDM [Charged Device Model] damage, the ESD program shall include a plan for the handling of process-required insulators. If the field exceeds 2,000 volts/inch, steps shall be taken to either: A) Separate the insulator from the ESD-sensitive device by a distance of 30 cm (12 inches); or B) Use ionization or other charge mitigating techniques to neutralize the charge.” (ANSI/ESDS20.20-2007 section 8.3)

 

“The primary method of static charge control is direct connection to ground for conductors, static dissipative materials, and personnel. A complete static control program must also deal with isolated conductors that cannot be grounded, insulating materials (e.g., most common plastics), and moving personnel who cannot use wrist or heel straps or ESD control flooring and footwear. Air ionization is not a replacement for grounding methods. It is one component of a complete static control program. Ionizers are used when it is not possible to properly ground everything and as backup to other static control methods. In clean rooms, air ionization may be one of the few methods of static control available.” (ESD Handbook TR20.20 Ionization, section 5.3.6.1)

 

“All ionization devices will require periodic maintenance for proper operation. Maintenance intervals for ionizers vary widely depending on the type of ionization equipment and use environment. Critical clean room uses will generally require more frequent attention. It is important to set-up a routine schedule for ionizer service. Routine service is typically required to meet quality audit requirements.” (ESD Handbook TR 20.20 section 5.3.6.7 Maintenance / Cleaning)

"Activities that handle items that are susceptible to less than 100 volts HBM may require additional control elements or adjusted limits.” [ANSI/ESD S20.20 section 2.0]

Show more details...
Hide details...
  • Neutralizing Ion Python and Hand Gun - Operation and Maintenance
  • TB-6530 - Neutralizing Ion Python and Hand Gun - Operation and Maintenance