MENU
Toggle navigation
Products
Bags and Labels
MIL-PRF-81705E Type III, Class 2
81705 Series Bags with Zipper
81705 Series Bags without Zipper
Statshield® Shielding Bags
Metal-In Standard ESD Shielding Bags
Metal-Out ESD Shielding Bags
Statshield® Moisture Barrier Bags
Moisture Barrier Bags 3.5 Mil
Foil Moisture Barrier Bags 4.0 Mil
High Puncture Moisture Barrier Bags 6.5 Mil
Desiccant Packs
Humidity Indicator Cards
Statfree® Ultra Clear Barrier Bags
Statfree® VPCI-125 HP Bags
VPCI-125 HP Bags without Zipper
VPCI-125 HP Bags with Zipper
Mailer
Labels
Cleanroom Products
Clean Pack Worksurface Mats
Cleanroom Booties
Wrist Straps and Coil Cords
Floor Finish and Maintenance
Dissipative Floor Finishes
Statguard® Dissipative Floor Finish
Statguard® Low-VOC Dissipative Floor Finish
Floor Care Products
Statguard® Floor Stripper
Statguard® Floor Cleaner
Statfree® Spray Buff
Statfree® Burnishing Restorer
Statguard® Floor Label
Education, Awareness, and Accessories
Conductive PCB Edge Protectors
ESD Workstation Cover
ESD Training
Labels
Posters and Signs
Dissipative Binders
Dissipative Document Holders
Aisle Marking Tape
Chair and Cart Covers
Reztore® Antistatic Coating
Floor Mats
Flat
Statfree® G2 Conductive Smooth Rubber
Statfree® CV280
Mat Accessories
Carpet Gripper Tape
Double Sided Adhesive Tape
Aisle Marking Tape
Anti-Fatigue
Statfree® i Conductive Ergonomic Rubber Interlocking Room System
Statfree® S Plus Dissipative Vinyl/Nitrile Anti-Fatigue
Foam
Statfree® Black Cushion Grade Static Dissipative Foam
Statfree® Conductive Foam
Foot Grounders
Full Coverage Foot Grounders
Heel Grounders
Sole Grounders
Stretch Fit Heel Grounders
Disposable Heel Grounders
Economy Heel Grounders
Toe Grounders
Shock Cord Foot Grounders
Grounding Hardware
Common Point Grounds
Bench Mounts
Dome Style
Standard Snap Style
Grounding Hubs
Laminate Grounding
Banana Plug Adaptors
Snaps
Ionization
Single Fan
High Output
Zero Volt Ionizer
Chargebuster® Plus
Mini
Overhead
Chargebuster®
Chargebuster® with Lights
Zero Volt Ionizer
Compressed Air
Chargebuster® Ion Gun
Viper Ion Gun
Ion Python
Pencil Type Ionizer
Ion Bars
Airless
Air Assisted
Controllers
Accessories
Measurement
Resistance Meters
Digital Surface Resistance Meter
Analog Surface Resistance Meter
Surface Resistance Checker
Portable Surface Resistance Probe
Low Resistance Tester
Static Field Meter
Body Voltage Meter
Charged Plate Analyzer
Portable Charged Plate Monitor
ESD Survey Kit
Smocks, Gloves, and Masks
Smocks
Gloves
Cut-Resistant Gloves
Static Dissipative Hot Gloves
ESD Inspection Gloves
Masks
Heavy Duty Poly Cotton ESD Smocks
ESD Pocket Protector
Tape
Wescorp ESD Cellulose Tape with Paper Cores
Wescorp ESD Cellulose Tape with Plastic Cores
Wescorp ESD Conductive Grid Tape
Wescorp Antistatic Hi Temp Masking Tape
Wescorp ESD Hi Temp Polyimide Tape
Wescorp ESD Tape Dispensers
Aisle Marking Tape
Continuous Monitors
Single-Wire Workstation
Mini Monitor
Multi-Mount Monitor
Dual Operator Monitor
Full-Time Monitor
Dual-Wire Workstation
Dual Operator Monitor
Zero Volt Monitor
AC Outlet
Worksurface Mats
Rubber
Statfree® HJ Dissipative Dual Layer Rubber
Statfree® T2 Plus Dissipative Dual Layer Rubber
Statfree® UC2 Dissipative Dual Layer Ultra Clean Rubber
Statfree® J Dissipative Shock Resistant Foam Rubber
Dissipative Dual Layer Rubber
Vinyl
Statfree® Z2 Dissipative 3 Layer Vinyl
Statfree® O Dissipative 3-Layer Vinyl
Statfree® B2 Plus Dissipative 2-Layer Vinyl
Wash Tray Liner
Disposable ESD Mats
Mat Accessories and Cleaners
Carpet Gripper Tape
Double Sided Adhesive Tape
Reztore® Surface & Mat Cleaner
Field Service Kits
Wrist Straps and Coil Cords
Single-Wire Wrist Straps & Coil Cords
Jewel® Elastic Adjustable Wrist Straps
Jewel® MagSnap® Wrist Straps
Premium Metal Expansion Wrist Straps
Ultra-Light Metal Expansion Wrist Straps
Elastic Adjustable Wrist Straps
Hook and Loop Wrist Straps
MagSnap® Wrist Straps with Right Angle Banana Plugs
Economy Wrist Straps
Disposable Wrist Straps
Coil Cords
Dual-Wire Wrist Straps & Coil Cords
Coil Cords
MagSnap® 360™
Jewel® Dual-Wire MagSnap® Wrist Straps
Jewel® Dual-Wire Metal Expansion Wrist Straps
Dual-Wire Metal Expansion Wrist Straps
Dual-Wire Adjustable Elastic Wrist Straps
Dual-Wire Wrist Straps with 7mm Snaps
Personnel Grounding Testers
Wrist Strap
Touch Tester
Portable Wrist Strap Tester
AC Outlet Analyzer and Wrist Strap Tester
Wrist Strap and Footwear
Combo Tester
Combo Tester X3
Closeout Items – Save 30%+
Closeout Ionizers
Closeout Smocks
Closeout Wrist Straps
Closeout Test Equipment
Closeout Coil Cords
Closeout Foot Grounders
Closeout Labels and Signs
Closeout ESD Shielding Bags
Closeout Mats and Ground Cords
Closeout Workstation Pouches and Document Holders
What's New
Blog
Distributors
Resources
Videos
Webinar
REGISTER / LOGIN
SHOP
RPL
CART (
0
)
SUBSCRIBE TO OUR EMAIL LIST - Be the first to know
about exclusive deals, tips, new products & more!
Questions And Answers
#
973
List All Questions
Search
List by Category
Question
How are you, greetings from Malaysia. I would very much appreciate if you could please answer this questions below. I came across a new experience yesterday but I could not figure out the reason why? Electrostatic charge on a plastic part container reads 3 kV. When my assistant holds with one hand reading drops to approx 600V. Holding with both hands now the reading increases to 3 kV. This is where I don't understand the theory. Next question..............When I measure the plastic container measuring 13"x15" reading varies at different points of the Tub. I understand the plastic tub is a non-conductive material but clipping it with ground wire to a grounding point will the charge be discharge to ground? Lastly, if this non-conductive plastic container is placed inside an antistatic tub as a safety measure will this prevent the container from being electrically charged ?
Answer
Your first question has many unknown variables, any of which could explain the phenomena you and your assistant are experiencing. My first assumption is that the container is truly insulative, i.e., it will not conduct current at any level. If this is correct, then what will cause the deviation of the electric field readings is the location of measurement device to the surface being measured. Since an insulative surface will not allow equal distribution of charge imbalance, but rather isolated islands of charge imbalance caused by say triboelectric generation at those specific areas, then moving the measurement device several inches from the initial location of measurement could yield a several thousand volt/inch field measurement deviation.Still basing the logic on the above assumption, then answers to your second and third question is no, clipping a ground wire onto an insulative tub will not discharge the charge imbalance and if the tub already has a charge on it, placing it into an antistatic safe enclosure will not prevent it from being charged, since it already is charged. It will however, minimize additional charging to the tub. Assuming the tub is dissipative, i.e., electrically conductive but at a high resistance range, say 1 gigohm, then the answers change. In answer to your first question, when your assistant holds the container with one hand, the charge is then redistributed over their body and thereby reduces the overall field strength, yielding a lower voltage reading. Now, here is where the many unknowns make it hard to finish the answer. Assuming the one hand grab is with the tub on a surface, such as a table, and when grabbed with two hands, the tub is lifted off this surface and held by your assistant free standing. This lifting action would charge the container and overall capacitance of the tub and operator yielding a higher voltage reading. If your assistant was to change their stance, (stand instead of sit or vice versa, rock their feet, shift their weight, etc.) this would change the overall capacitance and yield varying field measurements. In answer to question two, yes, by being conductive (even in the dissipative range), the tub would discharge charge when grounded. In answer to question three, placing a neutral tub into an antistatic container would minimize charge generation on the tub. Other possibilities include the following: The body's capacitance may have changed to effect the measured voltage. If the capacitance were to increase, then the total measured voltage will reduce and vice versa. Also, charge suppression may be in effect, where the body suppresses some of the charge, minimizing the overall electric field being measured.
Related Categories:
Electric Fields
Charge Suppression